Combustion Research Corp. Logo Combustion Research Corp.

Synergy.gif (57991 bytes)

MODEL NO. Btu/hr
NG
Btu/hr
LP
RECOMMENDED
MOUNTING HEIGHTS
SHIPPING WEIGHT
SYSPIC1A.gif (41568 bytes) 0SY030.
0SY035.
0SY040.
0SY045.
0SY050.
0SY055.
0SY060.
30,000
35,000
40,000
45,000
50,000
55,000
60,000
N/A
N/A
N/A
N/A
50,000
N/A
N/A


8- 14 FT /
2.44-4.27 M


30.00lbs. 13.6kg.
SYNPIC1B.gif (50991 bytes) 0SY070.
0SY075.
0SY080.
0SY085.
0SY090.
0SY090HL.
0SY095.
0SY100.
0SY100HL.
70,000
75,000
80,000
85,000
90,000
N/A
95,000
100,000
100/50,000
70,000
75,000
80,000
85,000
90,000
90/45,000
95,000
100,000
N/A



14-20 FT /
4.27-6.10 M

Standard
36.00lbs. 16.33kg

2  Stage
40.00lbs. 18.12kg
SYNPIC1C.gif (62084 bytes) 0SY110.
0SY120.
0SY120HL.
0SY125.
0SY130.
0SY135.
0SY150.
0SY150HL.
110,000
120,000
N/A
125,000
130,000
135,000
150,000
150/100,000
N/A
120,000
120/80,000
N/A
N/A
N/A
N/A
N/A

20-26 FT /
6.10-7.93 M

Standard
49.00lbs. 22.22kg

2  Stage
54.00lbs. 24.49kg
SYNPIC1D.gif (68815 bytes)
0SY160
0SY160HL.
0SY175.
0SY200.
0SY200HL.

160,000
N/A
175,000
200,000
200/100,000

160,000
160/80,000
N/A
160,000*
N/A
 

26-40 FT
7.93-12.20 M


Standard
62.00lbs. 28.12kg

2 Stage
67.00lbs. 30.39kg

Units designated in red are 2-Stage firing systems

 

SYSTEM DIMENSIONS

MODEL NUMBER HEIGHT LENGTH WIDTH *
0SY028 - 0SY033 8-3/4" / 22.22 cm 16-3/4" / 42.54 cm 28-5/8" / 72.72 cm
0SY055 - 0SY066 8-3/4" / 22.22 cm 25-1/4 " / 64.13 cm 28-5/8" / 72.72 cm
0SY083 - 0SY099 8-3/4" / 22.22 cm 33-7/8" / 86.04 cm 28-5/8" / 72.72 cm
0SY112 - 0SY160 8-3/4" / 22.22 cm 42-1/2" / 107.95 cm 28-5/8" / 72.72 cm

* Width includes controls

 

CONTROL SYSTEMS

CODE

VOLTAGE

Direct spark ignition controls, 100% safety lockout
 115V or 25V for NG (N) and LP (P)

1
2

115
24

Intermittent pilot, non 100% shut off. Only for NG (N)

3
4

115
24

*Millivolt self energizing, 100% safety shut off with standing pilot for NG (N) and LP (P)

5

*Millivolt

*Millivolt heaters are supplied with thermostat and 35" / 88.9 cm #18-2 control wire

 

All gas controls, rated for maximum 1/2" psig gas pressure, are mounted on the exterior of the heater for easy service accessibility.

All units are design certified by the CSA International (Formally the American Gas Association -A.G.A. & the Canadian Gas Association - CGA.

The ceramic burner is covered by a Ten-Year Warranty, while all other components are covered for one year.

 Click here to view the Owners Manual online!

BACK           HOME PAGE


Copyright ©
Combustion Research Corporation
2516 Leach Road, Rochester Hills, MI  48309-3555

Wwww.iheaters.com   www.irheating.com   www.reflectoray.com   www.residentialheater.com   www.residentialheater.net   www.tubeheater.org   www.serengetiir.com   www.serengetiheater.com   www.radiantheater.net