3.5 Inch Relect-O-Ray®
6 Inch Relect-O-Ray®
Reflect-O-Ray® EDS 3.5®
General System Information
| BURNER INPUT | 130K/120K BTU/Hr | 105,000 BTU/Hr | 75,000 BTU/Hr |
|||
| Max. | Min. | Max. | Min. | Max. | Min. | |
| Standard Output System Radiant Pipe Between Any Burner & Vacuum Exhauster | 90' | 70' | 80' | 60' | 70' | 50' |
| High Output (Reduced Tube Length) Systems | 80' | 60' | 70' | 40' | 60' | 40' |
| Maximum Flows Through One Radiant Tube | 2 | 3 | 4 | |||
| Minimum Distance Before Elbow | 35' | 30' | 25' | |||
| Minimum Distance Before Tee | 40' | 40' | 40' | |||
| Minimum Distance Before Damper | 30' | 30' | 30' | |||
NOTE: Please contact factory for verification of any variations which may be needed.
Typical Two Burner System |
|
Typical Four Burner System |
|
Note: The total length of emitter tubing, which corresponds to a heater within a multiple-burner system, is the total distance between any Burner and the flue-venting exhaust fan (and subject to the Minimum & Maximum length parameters for a single heater in the "General System Information" chart, above). However, the Total Length of Emitter Tubing for the multiple-burner system is the sum of the actual emitter tubing per a specifier's system layout. Enter only the total actual number of feet of emitter tubing for Equipment Selection.
Reflect-O-Ray® EDS
6®
General System Information
| BURNER INPUT | 360,000 BTU/Hr |
240,000 BTU/Hr |
||
| Max. | Min. | Max. | Min. | |
| Standard Output System Radiant Pipe Between Any Burner & Vacuum Exhauster | 230' | 180' | 200' | 150' |
| High Output (Reduced Tube Length) Systems | 190' | 150' | 160' | 130' |
| Maximum Flows Through One Radiant Tube | 2 | 2 | ||
| Minimum Distance Before Elbow | 30' | 30' | ||
| Minimum Distance Before Tee | 40' | 40' | ||
| Minimum Distance Before Damper | 30' | 30' | ||
NOTE: Please contact factory for verification of any variations which may be needed.
Typical Two Burner System |
|
Note: The total length of emitter tubing, which corresponds to a heater within a multiple-burner system, is the total distance between any Burner and the flue-venting exhaust fan (and subject to the Minimum & Maximum length parameters for a single heater in the "General System Information" chart, above). However, the Total Length of Emitter Tubing for the multiple-burner system is the sum of the actual emitter tubing per a specifier's system layout. Enter only the total actual number of feet of emitter tubing for Equipment Selection.